The industrial wireless temperature sensors from SENSA.iO are designed to measure the temperature of gas and liquid in production pipelines and have two connection options; in-line and surface-mounted.
Designed for quick and simple installation directly into the pipeline, these industrial temperature sensors also feature wetted material with high corrosion resistance.
ATEX-certified, they are ideal for hazardous locations such as environments with flammable gas or vapor, including chemical, petrochemical, paint, and steel plants.
SENSA.iO LoRaWAN temperature sensors can improve plant safety and efficiency using AI simulation for ultimate on-site management and remote communication up to 10km. They are also straightforward to maintain due to their modular and wireless design. Batteries can be replaced easily without removing the sensor from the pipeline and installed anywhere in the plant or factory.
Using an Android or iOS smartphone or device with Bluetooth 5.0, SENSA.iO industrial wireless temperature sensors can easily be configured and monitored anywhere in the world.
Options de Mesure |
Détecteur de Température à Résistance (RTD) Alliage de Nickel à Thermocouple (Type K) |
|
Plages de Mesure |
-40 °C … 650 °C / -4 °F … 1200 °F | |
Précision |
PT100 Class A ±(0.15 + 0.002 × t)°C Type K Class 1 ±1.5°C ou 0.4% de lecture |
|
Tube immergé, diamètreImmersion tube, length |
Ø6 mm Min. 100mm – Max. 1000mm / 4in to 40in |
|
Option de montage |
In-line Spring Loaded Monté en surface |
|
|
||
| Compatible | Android 7.0 or IOS 12 ou plus récent | |
| Sur | Des appareils Android ou Apple qui supportent le Bluetooth intelligent | |
|
|
||
| Class | A – bidirectionnelle à faible consommation | |
| Portée | Jusqu'à 10km | |
| Vitesse de transmission | De 0.3 kbps à 50 kbps | |
| Débit de donnée adaptable (ADR) | Disponible | |
| Immunité aux interférences | Très forte | |
| Mode | OTAA with External Join Server | |
| Rythme d'actualisation | 100 fois/par jour (default) | |
| Plans de fréquence | EU863-870 US902-928 AU915-928 AS9123-1 AS923-2 AS923-3 KR920-923 IN865-867 RU864-870 AS923-4 |
|
| RF Power | Max. 14dBM ERP | |
| Security: Dedicated trusted secure element | AES 128 bit encryption Roaming activation via HSM |
|
| Antenna: Omni-directional multiband | ||
Format |
Batterie de poche remplaçable sur site |
Type |
Primary Li-MnO2 |
Capacité nominale @ 20°C |
12.4 Ah |
Voltage nominal @ 20°C |
3.0 V |
Température de stockage |
+25 °C recommandé |
Température ambiante |
-40 … + 59°C | |
Température de stockage (recommandé) |
+ 25°C | |
Note de protection |
IP65 & IP67 NEMA 4x | |
Vibration |
20 g, 5…2000 Hz, X/Y/Z | |
Endurance @ 25 °C |
>10 millions FS cycles | |
Choc |
50g/11ms – 100g/6ms | |
Hexagonal Spring Loader
|
||
Surface Mounted with
|
||
Dimensions générales |
Longueur | 149 mm | |
Kit d'outils |
Clé plate | 59 mm | |
| Lock Spanner | SNS | ||
| Serrage maximum | 50Nm |
Conformité |
RoHS directive 2011/65/EU – RED directive 2014/53/EU ETSI CEI 61010-1 |
Sécurité |
ATEX II 1 GD, ATEX I M1, Ex ia I Ma, UKCA |
| IECEX Ex ia IIC T4 Ga, Ex ia IIIB T135 °C Da | |
| Class I/II/III Groups ABCDEFG T4 Tamb= 59°C / 139°F | |